Cable Management

15 Excel Electric - Cable Management 45⁰ Bend In/Out Lid 4-Way Inter- section Box Blank End Flange Coupler Short Coupler Cable Retainer Hanger Bracket Flange Outlet Stock Level E206 E207 E208 E209 E210 E214 E215 E209F Ex-Stock E3206 E3207 E3208 E3209 E3210 E3214 E3215 E3209F Ex-Stock E306 E307 E308 E309 E310 E314 E315 E309F Ex-Stock E4206 E4207 E4208 E4209 E4210 E4214 E4215 E4209F Ex-Stock E4306 E4307 E4308 E4309 E4310 E4314 E4315 E4309F Ex-Stock E406 E407 E408 E409 E410 E414 E415 E409F Ex-Stock E6206 E6207 E6208 E6209 E6210 E6214 E6215 E6209F Ex-Stock E6306 E6307 E6308 E6309 E6310 E6314 E6315 E6309F Ex-Stock E6406 E6407 E6408 E6409 E6410 E6414 E6415 E6409F Ex-Stock E606 E607 E608 E609 E610 E614 E615 E609F Ex-Stock E8206 E8207 E8208 E8209 E8210 E8214 E8215 E8209F 7 Days E8306 E8307 E8308 E8309 E8310 E8314 E8315 E8309F 7 Days E8406 E8407 E8408 E8409 E8410 E8414 E8415 E8409F 7 Days E8606 E8607 E8608 E8609 E8610 E8614 E8615 E8609F 7 Days E806 E807 E808 E809 E810 E814 E815 E809F 7 Days E9206 E9207 E9208 E9209 E9210 E9214 E9215 E9209F 7 Days E9306 E9307 E9308 E9309 E9310 E9314 E9315 E9309F 7 Days E9406 E9407 E9408 E9409 E9410 E9414 E9415 E9409F 7 Days E9606 E9607 E9608 E9609 E9610 E9614 E9615 E9609F 7 Days E906 E907 E908 E909 E910 E914 E915 E909F 7 Days E12206 E12207 E12208 E12209 E12210 E12214 E12215 E12209F 7 Days E12306 E12307 E12308 E12309 E12310 E12314 E12315 E12309F 7 Days E12406 E12407 E12408 E12409 E12410 E12414 E12415 E12409F 7 Days E12606 E12607 E12608 E12609 E12610 E12614 E12615 E12609F 7 Days E12806 E12807 E12808 E12809 E12810 E12814 E12815 E12809F 7 Days E12906 E12907 E12908 E12909 E12910 E12914 E12915 E12909F 7 Days E1206 E1207 E1208 E1209 E1210 E1214 E1215 E1209F 7 Days To determine the size of trunking required 1. Multiply the quantities of each cable size to be installed by the common cable factor (Table A) 2. Add them altogether 3. Choose the correct trunking size that must have a capacity factor equal or greater than the total value (Table B) Example An installer wants to lay the following cables 26 x 25 mm² stranded cable, 30 x 1.5 mm² solid cable and 10 x 2.5² mm stranded cable, So, the calculation will be as follows, (26 x 73.9 = 1921.4)+(30x8=240) +(10x12.6=126)=2287.4 In this case, the installer should pick minimum trunking size of 75 x 75 which has a trunking capacity factor of 2371 Important Information To comply with the wiring regulations the installer must ensure that the trunking is not overloaded and extra pressure is applied to the cables. So installer should not exceed the 45% space factor which should be allowed for all calculations, the 45% space factor means that the cross sectional area of all the cables must not be bigger than 45% of the cross sectional area of the trunking. In Table B, trunking capacity units are based on the calculation of 45% of the minimum cross sectional area of the trunking. For compartmental trunking add /2C or /3C to the above codes

RkJQdWJsaXNoZXIy Mzk5MjA=